Line Filter - The Last Barrier in the Switch Mode Power Supply

Free Bodo's Power Magazines!

 

 

 

Switch mode power supplies result in conducted interference because they generate radio interference voltage on the mains side. This can interfere with other equipment supplied with mains power. Line filters help to suppress the generated radio interference voltage. These can easily be designed from passive components such as current-compensated line chokes and X / Y capacitors. This article concerns the design of a single-phase line filter.

By Stefan Klein, Application Engineer, Technical Marketing, Würth Elektronik eiSos

Parasitic currents at the switch mode power supply input Parasitic currents result in radio interference voltage via impedances. Figure 1 shows the main current flow of parasitic currents in a switch mode power supply.

Parasitic currents at the switch mode power supply input

Initially, a high frequency active current „iDM“ flows on the mains side with the pulse frequency of the switching regulator which results in differential mode interference. Caused by fast switching processes of semiconductor components, usually MOSFETs, high frequency oscillations occur in combination with parasitic effects. In principle, the differential mode current flows from the mains power line „L“ over a rectifier bridge, then over the primary winding of the isolating transformer, over the MOSFET and over the neutral conductor „N“ back to the mains. The MOSFET is mounted on a heat sink for the cooling. In turn, this is connected to the protective earth conductor „PE“. Capacitive coupling between the heat sink and the drain of the MOSFET occurs here and produces common mode interference. A capacitively coupled common mode current „iCM“ now flows over the earth line „PE“ back to the switch mode power supply input where it is coupled again via parasitic capacitance both on the mains power line „L“ as well as on the neutral line „N“. The common mode current „iCM“ now flows as shown in Figure 1 over both mains power lines, via the rectifier bridge to the MOSFET, where it is again parasitically coupled via the heat sink to the earth line „PE“.

Expected interference spectrum

The rectified mains voltage is applied at the drain-source section. The peak level of the rectified mains voltage corresponds to:

\begin{equation} V_P = 230V\cdot \sqrt2 = 325V\end{equation}

A switch mode power supply with pulse frequency of 100 kHz has been used as an example. For this pulse frequency, the timing signal corresponds to „T“ 10 μs. The pulse duration is 2 μs. Based on this, the duty cycle can first be determined:

\begin{equation} D = \frac{t_{on}}{\tau} = \frac{2\mu s}{10\mu s} = 0.2\end{equation}

Assuming that the current through the rectifier bridge is trapezoidal, the EMC spectrum without line filter and without further Fourier transformation can be approximately determined. The first break point of the envelope of the spectrum is needed first:

\begin{equation}\nu_{co1} = \frac{1}{\pi \cdot D} = \frac{1}{\pi \cdot 0.2} = 1.592\end{equation}

The first corner-over frequency of the envelope of the spectrum enclosing amplitude density is analogous to this:

\begin{equation} f_{co1} = \nu_{co1}\cdot f_{CLK} = 1.592\cdot 100kHz = 159.2kHz\end{equation}

The first harmonic amplitude can be determined from this:

\begin{equation} C_1 = \frac{2\cdot V_P}{\nu_{co1} \cdot \pi} = \frac{2\cdot325V}{1.592\pi} = 130V\end{equation}

Based on the assumption that the parasitic coupling capacitance „CP“ between the switch mode power supply and ground is 20pF, the first harmonic common mode current can now be determined:

\begin{equation} I_{cm1} = \frac{2\pi \cdot f_{co1}\cdot C_P \cdot c_1}{\sqrt{(50\pi \cdot f_{co1}\cdot C_P)^2 + 1}} = \frac{2\pi \cdot159.2kHz\cdot 20pF\cdot 130V}{\sqrt{(50\pi \cdot 159.2kHz\cdot 20pF)^2 + 1}} =2.6mA\end{equation}

The radio interference voltage is measured using mains simulation and an EMC test receiver. Due to the parallel connection of the 50 Ω input impedance of the EMC test receiver and the 50 Ω output impedance of the mains simulation, total impedance „Z“ of 25 Ω is produced. The measured radio interference voltage „Vcm“ can now be calculated:

\begin{equation} V_{cm} = Z\cdot I_{cm1} = 25\Omega \cdot 2.6mA = 0.065V\end{equation}

Converted to dBμV, this gives:

\begin{equation} V_{dB\mu V} = 20\cdot log\bigg( \frac{0.065V}{1\mu V}\bigg) = 96.26dB\mu V\end{equation}

The result of the calculation is that high conducted emission can be expected. For example, the product family standard EN 55022 can be used here for assessment of the interference emission. In the frequency range of 0.15 MHz to 0.5 MHz, it defines a permissible interference level of 66 dBμV to 56 dBμV of the quasi peak. Figure 2 shows the result of the measurement of the conducted radio interference voltage of this switch mode power supply without line filter.

Radio interference voltage of a switch mode power supply without line filter

The measurement shows that a line filter is absolutely essential.

Design of a line filter

Figure 3 shows the schematic design of a simple single-phase line filter. Würth Elektronik provides various models of line chokes, such as the WE-CMB series, for the construction of line filters. A line choke basically consists of a MnZn ring core on which there are two geometrically separated windings wound in opposite directions.

Single phase line filter

Figure 4 shows the design of the WE-CMB. In this case, the WE-CMB acts like a filter coil which counteracts the current and reduces its amplitude. A common mode choke with as low as possible SRF in the lowest frequency range should be used because the switch mode power supply used here switches with very low pulse frequency. Low SRF causes high attenuation in the lower frequency range.

Design of WE-CMB

A suitable WE-CMB of the XS design of 39 mH has been selected for this. Figure 5 shows the characteristic curve of its attenuation in the 50 Ω system.

Attenuation of the WE-CMB XS 39 mH

A distinction is always made in the attenuation between the common mode (black line) and differential mode (red, dashed line) suppression. In common mode operation, the WE-CMB line choke reaches its maximum attenuation at 150 kHz. However, the attenuation drops with increasing frequency. Other X / Y capacitors are required because the line filter should suppress interference up to 30 MHz. An X capacitor is placed both before as well as after the line filter to block differential mode interference from the mains side and the switch mode power supply. With its leakage inductance, the WE-CMB in combination with the X capacitor forms a low pass filter which reduces the differential mode interference and subsequent common mode interference. Two X capacitors with a value of 330 nF have been selected here as an example. Their SRF is approx. 2 MHz.

For safety reasons, a resistor must be placed on the mains side in parallel with the X capacitor to discharge the capacitor if the switch mode power supply is disconnected from the mains. A varistor should also be placed before the line filter so that transient overvoltages from the mains are short-circuited. Würth Elektronik disk varistors from the WEVD series are ideally suitable for this. Overload protection must also not be missing. This should always be placed before the varistor. The protection trips in the case of a short-circuit by the varistor. Y capacitors are required for further suppression of the common mode interference. In combination with the WE-CMB, they form a corner frequency „f0“ which is defined by the „Thomson“ oscillation equation:

\begin{equation} f_0 = \frac{1}{2\pi\sqrt{L\cdot C}}\end{equation}

Attenuation of 40 dB is required to achieve below the permissible interference level of 66 dBμV (at 150 kHz). This corresponds to a decade in the logarithmic representation. One tenth of the pulse frequency is used as factor for the corner frequency or further calculation of the Y capacitors. The oscillation equation is now converted and used to determine the X capacitance:

\begin{equation} C_Y = \frac{1}{\bigg( 2\pi \cdot \frac{f_{CLK}}{10}\bigg)^2 \cdot L_{CMC}} = \frac{1}{\bigg( 2\pi \cdot \frac{100kHz}{10}\bigg)^2 \cdot 39mH} = 6.5pF\end{equation}

As two Y capacitors are needed, the calculated value is divided by two. Y capacitors conduct common mode interference from the switch mode power supply back to the protective earth. As, depending on the device type, only leakage currents of 0.25 mA to ≤ 3,5 mA are permissible, no capacitance with a value greater than 4.7 nF should be used. Two Y capacitors with an E 12 value of 2.2 nF have been selected for this reason. Figure 6 shows the result of the measurement with this line filter.

Radio interference voltage with line filter

The EMC test of the radio interference voltage is passed with filter. The smallest signal to interference ratio of 10 dB of the quasi peak is present at the lowest frequency of 150 kHz. Quasi peak and average peak are far below the permissible interference level in the other frequency range.

Optimisation of the line filter

It is also possible to further increase the signal to interference ratio in the lower frequency range. Two X capacitors with 330 nF are replaced with two 1.5 1,5 μF X capacitors for this. Figure 7 shows the measurement of the optimised line filter.

Radio interference voltage with optimised line filter

The change of the capacitance causes a reduction of the radio interference voltage of approx. 15 dB in the lower frequency range. A greater signal to interference ratio has been achieved and a good line filter designed.

Error due to dispensing with line choke

It is often tried at the beginning to only use X and Y capacitors to suppress interference in order to dispense with a common mode choke. However this is contrary to the principle of the line filter of counteracting the interference current by adding a high-impedance filter element. The radio interference voltage using the same filter without common mode choke has been measured as an experiment. Figure 8 shows the measurement.

Radio interference voltage with line filter without WE-CMB

As expected, the interference emission in the lower frequency range increases strongly without the WE-CMB line choke. At 200 kHz, the quasi peak shows a value of approx.78 dBμV and the average peak shows a value of 60 dBμV. The permissible interference level is exceeded up to 600 kHz both by the quasi peak as well as by the average peak. A line filter without line choke is inadequate!

Additional differential mode filter

If the differential mode suppression using the WE-CMB and the X capacitors is not sufficient, an additional differential mode filter consisting of two coils connected in series helps. Figure 9 shows the design.

Line filter with WE-CMB and WE-TI HV

The Würth Elektronik coils WE-TI HV and WE-PD2 HV or the WE-SD series are ideally suitable for the differential mode suppression. The WE-UKW series is recommended in the case of high frequency interference. The „Thomson“ oscillation equation can be used again here to calculate the coils. If attenuation of 40 dB / decade would be required from each coil, the calculation should be made with a corner frequency of one tenth of the pulse frequency. The already used X value of the X capacitors can be used for the calculation of the coil:

\begin{equation} L_{DM} = \frac{1}{\bigg( 2\pi \cdot \frac{f_{CLK}}{10}\bigg)^2 \cdot C_{X}} = \frac{1}{\bigg( 2\pi \cdot \frac{100kHz}{10}\bigg)^2 \cdot 330nF} = 767\mu H\end{equation}

As the coils for the differential mode current are in series, the calculated value is divided by two. The next larger inductance value of a WETI HV would be 470 μH. It should be ensured for the selection of a differential mode coil that its rated current „IR“ is far above the rated current of the switch mode power supply input.

Result of the line filter

In conclusion, a line filter for switch mode power supplies without a common mode choke is not sufficient. Individual capacitors are not sufficient to completely suppress the interference emission. Additional longitudinal coils before the line filter help if further suppression of the differential mode interference is required. Using a line filter, all interference levels are below the permissible limit value and the switch mode power supply can pass an EMC test.

Literature
Würth Elektronik eiSos GmbH & Co. KG „Trilogy of Inductors“, Application manual for EMC filters, pulsed power supplies and HF circuits, 4th extended and revised edition, Dr. Thomas Brander, Alexander Gerfer, Bernhard Rall, Heinz Zenkner

 